Specifications :
General
- Dimensions master: 338 mm x 333 mm x 154 mm | slave: 175 mm x 154 mm x 246 mm
- Total weight master: 5.4 kg | slave: 2.7 kg
- Protection class IP 67
- Power supply 6 … 30 V
- Power consumption at 12V standby approx. 1mA; active operation approx. 140mA
- operating temperature – 35 … 60°C
- Miscellaneous over voltage protection, reverse power protection, lightning protection
Waterlevel measurement
- Measuring range 0 … 15 m standard version / 0 … 35 m extended version
- Resolution 1 mm
- Radar frequency 26 GHz (K-Band)
- Radar opening angle 10°
Velocity measurement
- Measuring range 0.08 … 16 m/s (depending on flow conditions)
- Accuracy +/- 0.01 m/s; +/- 1 % FS
- Resolution 1 mm/s
- Direction recognition +/-
- Measuring duration 5 … 240 sec.
- Measuring interval 8 sec. … 5h
- Measuring frequency 24 GHz (K-Band)
- Radar opening anlge 12°
- Distance to water surface 0.50 … 35 m
- Minimum swell needed 3 mm
Automatic vertical angle compensation
- Accuracy +/- 1°
- Resolution +/- 0.1°
Interface
- Interface 1x SDI-12 1 x RS 485 or Modbus
- Transfer rate 1.2 to 115.2 kBd
- Protocol diverse ASCII-protocols
- Output discharge rate, flow velocity, waterlevel, quality parameters
Catalog : PDF
Reviews
There are no reviews yet.