Light Sensor Logger

Specifications:

  • Current Inputs: 3 BNC connectors (used to connect LI-COR sensors)
  • Output Channels:
    • Light
    • Math Channels: 8 math channels (addition, subtraction, multiplication, division, natural logarithm, integration, daily integration, attenuation)
    • GPS (optional)
    • Prompt
    • Battery Voltage
  • Input Channel Specifications:
    • Frequency Rejection: >70dB at 50 or 60 Hz (1 input channel @ sampling rates of 1, 2, 5, 10, 20Hz)
    • Current Accuracy: ±0.3% of full scale reading @25°C
    • Signal Ranges:
      • Range # Current Range Resolution (Typical)
        1 0 – 0.250 µA (micro-amps) 0.0305 nA (nano-amps)
        2 0 – 2.50 µA (micro-amps) 0.1525 nA (nano-amps)
        3 0 – 25 µA (micro-amps) 1.525 nA (nano-amps)
        4 0 – 250 µA (micro-amps) 15.25 nA (nano-amps)
    • Raw Mode (1 – 500 Hz): Selectable Range
    • Standard Modes (Continual, Manual, Daily, One Time):
      • Auto range for total sampling rate ≤ 3 Hz (ex. 1 Hz sampling on 3 input channels)
      • Fixed range (selectable) for total sampling rates > 3 Hz (e.g. 2 Hz sampling on 2 input channels)
  • Sampling Rates:
    • Standard Modes: 0.01 Hz, 0.1 Hz, 1 Hz, 2 Hz, 5 Hz, 10 Hz, 20 Hz
    • Raw Mode: 1 – 500 Hz (1 Hz through 500 Hz in whole number increments)
  • Logging Rates:
    • Standard Modes Sampling: Every Sample, 100 msec, 200 msec, 500 msec, 1 sec, 5 sec, 10 sec, 15 sec, 30 sec, 60 sec, 100 sec, 5 min, 15 min, 30 min, 1 hr, 2 hr, 3 hr, 6 hr, 12 hr, 24 hr
    • Raw Mode Sampling: Every sample (1 – 500 Hz)
  • Averaging:
    • Raw Mode Sampling: No averaging
    • Standard Modes: depends on sampling rate (see table below)
      SMP\AVG 100 msec 200 msec 500 msec 1 sec 5 sec 10 sec 15 sec 30 sec 60 sec 100 sec 5 min 15 min 30 min 1 hr 2 hr 3 hr 6 hr 12 hr 24 hr
      0.01 Hz X X X X X X X X X
      0.1 Hz X X X X X X X X X X
      1 Hz X X X X X X X X
      2 Hz X X X X X X X X
      5 Hz X X X X X X X X
      10 Hz X X X X X X X X X
      20 Hz X X X X X X X X X
  • Display: 128 × 64 graphics display
  • Real-Time Clock:
    • Year, Month, Day, Hour, Minute, Seconds
    • Accuracy of ±3 minutes per month
  • Data Storage Capacity: 1 GB (FAT16 file system)
  • Communications: USB (as mass storage device)
  • Global Positioning System (Option) — GPS RADIONOVA® RF Antenna Module:
    • Horizontal position accuracy: 2.5 m CEP (50% Circular Error Probability, Open-Sky, 24hr Static, good view of the sky).
    • Maximum position update rate: 1 Hz.
    • GPS receiver sensitivity, autonomous acquisition: -148dBm.
    • WAAS enabled receiver
    • Time to first fix (TTFF), hot start: 1 second.
    • TTFF, warm start: 6 seconds (typical).
    • TTFF, cold start (with good view of the sky): 37 seconds at 90% probability.
  • Power Supply Options:
    • 4 “AA” size batteries
    • USB, AC-DC power adapter
    • USB, external battery power pack (customer supplied)
  • Battery Life:
    • 80 hours life (typical usage of 1 Hz sampling rate and logging rate)
    • 40 hours life (typical usage with GPS option on)
  • Environmental Conditions:
    • Operating Temperature Range: -20 to 50°C
    • Humidity Range: 0 to 95% RH (non-condensing conditions)
    • Storage Temperature Range: -40 to 65°C
  • Size: 20.9 × 9.8 × 3.5 cm (8.2″ × 3.9″ × 1.4″)
  • Weight: 0.454 kg (1.0 lb) with batteries

The LI-1500 connects up to three light sensors with BNC terminals. Package includes four AA batteries, USB cable, AC power supply adapter, carabiner clip, carrying case, Windows® file viewer software, and instruction manual. Sensors sold separately.