Specifications :
Model | TS8216 |
Optical Geometry | Reflect: di:8°, de:8°((diffuse illumination, 8°direction reception) ; |
SCI (specular component included)/SCE (specular component excluded) ;Include UV/exclud UV | |
Transmittance: di:0°, de:0° (diffuse illumination: 0°direction reception) ; | |
SCI (specular component included)/SCE (specular component excluded) ; Include UV/exclud UV | |
Haze(ASTM D1003), | |
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724/1,ASTM E1164,DIN5033 Teil7 | |
Application | It is used for the color control of small-area reflective samples and small-volume transmission samples. |
Integrating Sphere Size | Φ154mm |
Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nm cut-off light source |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Interval | 10nm |
Semiband Width | 5nm |
Measured Reflectance Range | 0-200% |
Measuring Aperture | Reflective : Φ0.3mm/Φ0.5mm/Φ1mm (only choose one aperture) |
Transmissive : Φ8mm/Φ4mm (only choose one aperture) | |
Specular Component | Reflectance: SCI/SCE, Transmittance: SCI/SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), |
YI (ASTM D1925, ASTM 313), | |
Metamerism index Mt, | |
Staining Fastness, Color Fastness, Color Strength, Opacity, | |
APHA/Hazen/Pt-Co (Platinum Cobalt Index), Gardner Index | |
8° gloss, 555 color classification, haze (ASTM D1003), Saybolt (Sybert index), ASTM D1500 color scale, Chinese Pharmacopoeia color scale | |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ1mm/SCI, Standard deviation within 0.08% |
Chromaticity value:Φ1mm/SCI, Standard deviation within ΔE*ab 0.15 (After the instrument is warmed up and calibrated, measure the average value of the whiteboard 30 times at an interval of 5s) | |
Spectral transmittance: Φ8mm/SCI, Standard deviation within 0.1% | |
Chromaticity value:Φ8mm/SCI, Standard deviation within ΔE*ab 0.18(After the instrument is warmed up and calibrated, measure the average value of the whiteboard 30 times at an interval of 5s) | |
Inter-instrument Error | Φ1mm/SCI, Within ΔE*ab 0.25(Measured average value of 12 tiles of BCRA series Ⅱ) |
Dimension | L*W*H=370x300x200mm |
Weight | Approx. 9.6kg |
Power | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB, Bluetooth®5.0, print serial port |
Data Storage | Standard 5000 Pcs, Sample 40000 Pcs(SCI/SCE counts as one piece of data) |
Language | Simplified Chinese, Traditional Chinese, English, (German, French, Spanish can be customized) |
Operating Environment | 0~40℃(32~104°F) |
Storage Environment | -20~50℃(-4~122°F) |
Standard Accessory | Power adapter, manual, quality management software (download from official website), data cable, standard calibration board, black calibration box, transmission black baffle, sample holder, single reflection aperture, transmission test fixture assembly, single transmission test fixture assembly |
Optional Accessory | Mini printer, instrument upside down test fixture, petri dish |
Notes | The specifications are subject to change without notice. |
Catalog : PDF