Sommer Messtechnik

Flow Meter SQ-R

Features :

  • Non-contact measurement, maintenance-free system.
  • Calculation of discharge by continuous measurement of flow velocity and water level.
  • No construction measures necessary in the sewer.
  • Waterproof and resistant housing also for use in aggressive environments.
  • Wide measuring range from a few liters up to several cubic meters per minute.
  • High data availability even with intensive turbidity and high solids content.
  • Easy integration into existing measuring and control systems.
  • Self-check function supports correct installation and high data quality.
  • Versatile measurement output via RS-485, Modbus, SDI-12, pulse and analog signal.
  • Integrated hydraulic model for precise flow calculations.
  • Easy configuration with SQ-Commander software.
SKU: SMT-SQ-R-Flow Meter Category: Tags: , , , , , ,

Specifications :

GENERAL
  • Dimensions 272 x 153 x 186 mm (1 bracket for pipe with Ø 30 mm).
  • Total weight 1.55 kg.
  • Protection class IP 68.
  • Power supply 6 … 30 V DC.
  • Power consumption 1.5 Ah per day (for a measurement interval of 60 s).
  • Operating temperature -35° … 60° C.
  • Storing temperature -40° … 60° C.
  • Protection over voltage protection, reverse power protection, lightning protection.
Level measurement
  • Measuring range 0.05 … 8 m (0.16…26.25 ft).
  • Radar frequency 80 GHz (W-band).
  • Beam angle 8.
  • Near field blanking 0.05 m.
  • Resolution ≤ 2 mm.
VELOCITY MEASUREMENT
  • Measuring principle Doppler-radar.
  • Measuring range 0.08 … 16 m/s (depending on flow conditions).
  • Accuracy +/- 0.01 m/s; +/- 1 % FS.
  • Resolution 1 mm/s.
  • Direction recognition +/-.
  • Measuring duration 5 … 240 sec.
  • Measuring interval 8 sec. … 5 h.
  • Measuring frequency 24 GHz (K-Band).
  • Radar opening angle 12°.
  • Distance to water surface 0.05 … 35 m (0.16…114.83 ft).
  • Required minimum swell 3 mm.
AUTOMATIC VERTICAL ANGLE COMPENSATION
  • Accuracy +/- 1°.
  • Resolution +/- 0,1 °.
INTERFACES
  • Analogue outputs  2 x 4 … 20 mA.
    • 1 x water level.
    • 1 x flow rate or flow velocity.
  • Pulse output pulse per volume (selectable units).
  • Digital Interfaces 1 x SDI-12; 1 x RS 485 or Modbus.
    • Transfer rate: 1.2 to 115,2 kBd.
    • Protocol: various ASCII-protocols.
    • Output: discharge, flow velocity, water level, quality parameter.

Catalog : PDF

Brand

Sommer Messtechnik

Sommer Messtechnik

Reviews

There are no reviews yet.

Be the first to review “Flow Meter SQ-R”

Your email address will not be published. Required fields are marked *

Scroll to Top