Specifications :
| Model | YS6080(Pulsed xenon lamp) | |
| Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle); SCI (specular component included)/SCE (specular component excluded);Include UV / excluded UV light source; Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing); SCI (specular component included)/SCE (specular component excluded);Include UV / excluded UV light source; Haze(ASTM D1003); Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | |
| Integrating Sphere Size | Φ 154mm | |
| Light Source Device | 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp,420nm cut-off Xenon Lamp,460nm cut-off Xenon Lamp | |
| Spectrophotometric Mode | Concave Grating | |
| Sensor | 256 Image Element Double Array CMOS Image Sensor | |
| Wavelength Range | 360-780nm | |
| Wavelength Pitch | 10nm | |
| Semiband Width | 5nm | |
| Reflectance Range | 0~200% | |
| Measuring Aperture | Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive : Φ30mm/Φ25mm;Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
| Specular Component | Reflectance: SCI&SCE Transmittance: SCI&SCE | |
| Color Space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy | |
| Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 | |
| Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), TI (ASTM E313, CIE/ISO), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) APHA/Hazen/Pt-Co, Saybolt | |
| Observer Angle | 2° & 10° | |
| Illuminants | D65,A,C,D50,D55,D75, F1,F2,F3,F4,F5,F6, F7,F8,F9,F10,F11,F12, CWF,DLF,TL83,TL84,TPL5,U30 | |
| Displayed Data | Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset | |
| Measuring Time | About 2.4s (Measure SCI & SCE about 5s) | |
| Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.06% (400 nm to 700 nm: within 0.05%) Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.012 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.06% (400 nm to 700 nm: within 0.06%) Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
| Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.12 (Average for 12 BCRA Series II color tiles) | |
| Size | 370×300×200mm | |
| Weight | About 9.6kg | |
| Power Supply | DC 24V, 3A Power Adapter | |
| Light Source Device Life | 5 years, more than 3 million times measurements. | |
| Display | 7″ TFT Capacitive Screen-touch Display | |
| Data Port | USB & Bluetooth & Print serial port | |
| Data Storage | Standard 5000 Pcs, Sample 40000 Pcs | |
| Language | Simplified Chinese, Traditional Chinese, English, (Optional Customized German, French and Spanish) | |
| Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation) | |
| Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) | |
| Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component | |
| Optional Accessory | Micro-printer, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components, culture dish | 