Ampere Detector Ion Chromatography IC6610

Features :

  1. Ideal model for high efficiency, high sensitivity, high reliability ion chromatography; dual system one machine realizes yin and cation simultaneously.
  2. Conductance and electrochemical detectors meet the detection requirements of different substances.
  3. Can realize two-dimensional ion chromatography (valve switching) and post-column chemical derivatives.
  4. Dual system simultaneously detection design allows customers to maximize efficiency, further shorten detection time.
  5. Double pump, column temperature box, modular design of the crash generator, the user can choose the required system configuration.
  6. It can be equipped with high-end double pump double system detection, and can also customize single pump single system detection according to customer needs, and personalize your chromatography solution.

Specifications :

Ampere Detector Ion Chromatography IC6610
Working Power 220V, 50Hz
Environment Temperature 10-40°C
Relative Humidity 20-85%
Qualitative Repeatability ≤0.1%
Quantitative Repeatability ≤0.5%
Pump System
Full PEEK Pump Flow (0.001~12.000) mL/min
Pump Head Pressure Resistance (0~40) MPa
Flow Rate Setting Error <0.1%
Flow Rate Stability <0.1%
Pressure Display Accuracy 0.001Mpa
Pressure Pulsation <0.25%
Ampere Detector
Type Thin-layer structure with automatic range.
Drive Voltage Range -2.0V — 2.0V
Drive Voltage Resolution 0.001V
Output Signal Range Integral mode: 50pc — 200uC
DC mode:1pA–74uA
Noise Integral mode <30pC
DC mode <5pA
DC mode static noise <1pA
Cell Material Titanium
Working Electrodes Gold, glassy carbon, silver, platinum
Reference Electrode Saturated potassium chloride Ag/AgCl reference electrode
Cell Volume <0.2uL
Max Cell Pressure 0.7MPa
Mini Detection Concentration I – 0.001 μg/mL
Mini Detectable Concentration Fructose – 0.01μg/mL
Minimum Detectable Concentration CN – 0.0005 μg/mL.
Qualitative Reproducibility ≤0.1%
Quantitative Repeatability ≤0.5%
Suppressor
Constant Current Source Range 0-500mA in 0.1mA increments
Dead Volume 50uL
Supression Capacity 170ueq/min
Pressure Resistance 3MPa
Column Oven
Temperature Range Room temperature +5℃~70℃
Control Temperature Stability 0.1℃/h
Temperature Set Value Error 0.05℃
Autosampler
Sample Vials ≥ 120 (1.5ml sample bottle)
Repeatability Full-loop injection <0.3% RSD (injection volume >5uL)
Syringe Specifications standard: 500ul; optional; 250ul, 1000ul, 2500ul
Quantification Loop Specifications Standard: 100ul; optional: 20ul, 50ul, 200ul

Catalog : PDF